Products Description
The lean amine particulate filter is engineered for reliable particulate removal in amine gas treating systems. It protects downstream equipment-such as heat exchangers, contactors, and reclaimers-from scale, corrosion, and fouling by capturing solids as small as 5 µm.
Key features

High Dirt-Holding Capacity
Multi-layer mesh design traps more debris before reaching final pressure differential.

Thermal Stability
Rated for continuous operation up to 120 °C without media degradation.

Low Pressure Drop
Optimized pleat geometry ensures minimal ΔP across element at rated flow.

Versatile End Fittings
Compatible with all major OEM housings for drop-in replacement.
Technical parameters
| Parameter | Specification |
| Filtration Rating | 5 µm, 10 µm (optional: 1 µm, 20 µm) |
| Maximum Operating Temperature | 120 °C |
| Maximum Operating Pressure | 15 bar (217 psi) |
| pH Range | 3–9 |
| Outer Diameter (OD) | 219 mm, 254 mm, 305 mm options |
| Inner Core Material | Glass-filled polypropylene |
| End Cap Styles | 222/Fin, 226/Flat, SOE |
| Recommended Flow Rate | 5–30 m³/h per element |
applications
- Natural Gas Sweetening Plants (Onshore & Offshore)
- Refinery Sour Water Stripper (SWS) Units & Tail Gas Treating
- Syngas Purification (CO₂ Capture)
- Petrochemical & Chemical Plant Acid Gas Removal Units
- Landfill Gas & Biogas Upgrading
Success Stories
Case1: Midwest Gas Plant (USA)
Challenge: Frequent fouling of heat exchangers leading to weekly shutdowns.
Solution: Installed 8 × 10 µm lean amine particulate filters in series.
Result: Extended exchanger cleaning intervals from 7 to 45 days; annual savings $180 k.
Case2: European Refinery
Challenge: Amine reclaimers clogged by iron sulfide fines.
Solution: Upgraded to 5 µm amine filter cartridges with Viton seals.
Result: Reclaimer uptime improved by 22%, reducing reagent usage by 15%.

FAQ
Q: Will the media degrade in hot MDEA?
A: Our primary media is specifically formulated for long-term thermal and chemical stability in common amines up to 120°C. We provide compatibility charts.
Q: How often should I change elements?
A: Depend on contamination load. Monitor differential pressure (dP). We recommend changeout at 35-40 psid dP across the vessel. Typical runs range 3-12 months.
Q: Can you handle high FeS loads?
A: Absolutely. Our depth loading design excels at capturing large volumes of fine FeS sludge common in systems with corrosion issues.
Hot Tags: lean amine particulate filter, China lean amine particulate filter manufacturers, suppliers, factory, sintered metal filter cartridge, stainless steel sintered filter element, pleated filter cartridge, pleated high flow filter element, spun bonded filter cartridge, spun filter cartridge



